How a Smoke Damper Works
As with testing dynamic fire dampers, testing a smoke damper ought to be carried out beneath normal airflow conditions to verify no impediment to operation exists because of rust or broken blades. SummaryThere are numerous methods to modulate hearth and smoke dampers and apply fireplace and smoke security controls. In containment applications, the damper is closed when either high temperatures or smoke is noticed. In smoke control systems numerous methods exist to either open or shut the damper to purge or pressurize areas to forestall smoke from spreading. If smoke is detected energy is faraway from the actuator and the alarm contact on the detector closes to concern an alarm. If an area smoke detection system is used, the smoke control system has a relay related instead of the smoke detector contact. In case smoke isn't detected but the temperature at the damper rises to 165°F (74°C), then the temperature responsive switch opens.
Balancing Ventilation and Smoke Control with Corridor Dampers
In Figure 7 instead of a minimal potentiometer controlling the actuator, a building automation system, direct digital control sends the sign to terminal three and the actuator is constantly adjustable. A full loop is always needed for current move out and into any device. Figure 5 Potentiometer control of a smoke damper with override closed. When comparing Types A, B, and C/CR, it is essential to contemplate the specific environments and requirements of the HVAC methods they are supposed for. The value typically goes up as you go down the alphabet with Type A being the most affordable and Type C being the most costly.
Type C and CR Fire Dampers
The temperature swap is guide reset so the damper stays closed during the occasion. Dynamic, a number of blade fire dampers provide another solution to the access and upkeep issues posed by the dynamic curtain blade dampers. Multiple blade fireplace dampers are easy to each test and reset since the blades may be operated and held open by way of a hand lever or a pair of pliers whereas the fuse link is changed. An additional resolution for round ducts is the utilization of a real spherical hearth damper. Round hearth damper permits the fusible hyperlink to be replaced easily then the damper can be adjusted to its full-open position. Containment fire and smoke damper controlsFigure 1 reveals (from left to right) a duct smoke detector, excessive temperature switch,[1] and actuated damper. Roughly 80% of fireside and smoke dampers are put in this fashion although the smoke sensing may be through space smoke detection and a relay employed to operate the damper.